Detec Systems Tutorials

Applying TruGround Conductive Primer

TruGround Conductive Primer is a water based primer designed to create the required conductivity directly below the membrane for valid ELD testing.  Below are instructions for the proper application of TruGroundClick here to download the application notes.

  1. Gather required tools (electric mixer, paint rollers, paint brushes, boot covers)
  2. Ensure the surface of the membrane is clean and dry
  3. Flip each pail upside down for 5 minutes to allow settled material to loosen
  4. Thoroughly mix each pail using an electric mixer
  5. Apply TruGround to all T-joints to ensure continuity between seams
  6. Apply TruGround from the substrate surface on to all metallic penetrations to create ground connections for ELD testing
  7. Thinly coat the surface of the substrate
  8. Once dry (typically 30 minutes), apply required adhesives/primers, and then the membrane

Notas de aplicacion de TruGround en espanol

El impermeabilizante conductivo TruGround es un impermeabilizante a base de agua diseñado para crear la conductividad requerida directamente debajo de la membrana para pruebas ELD válidas. A continuación se encuentran las instrucciones para la correcta aplicación de TruGround.

  1. Reúna las herramientas necesarias (batidora eléctrica, rodillos para pintar, brochas, cubrebotas).
  2. Asegúrese de que la superficie de la membrana esté limpia y seca.
  3. Voltee cada balde boca abajo durante 5 minutos para permitir que el material sedimentado se afloje.
  4. Mezcle bien cada balde con una batidora eléctrica.
  5. Aplique TruGround a todas las uniones en T para garantizar la continuidad entre las costuras.
  6. Aplique TruGround desde la superficie del sustrato a todas las penetraciones metálicas para crear conexiones a tierra para pruebas ELD.
  7. Recubra finamente la superficie del sustrato.
  8. Una vez seco (típicamente 30 minutos), aplique los adhesivos/imprimadores requeridos y luego la membrana.
IT'S A GAME CHANGER!
A new patented formulation that enables what was, until now, not possible: 
A truly reliable membrane integrity test for conventional membrane assemblies!

TruGround is the only approved/conclusive method to perform membrane integrity testing on conventional roofs. Stop playing games with other testing methods. Spec the one that works. Fast. Affordable. Reliable. Who says you can't have it all?